Ch 8 - removing and replacing servo drives, Before you begin, Chapter 8 – Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual
Page 153: Removing and replacing servo drives, Chapter
Rockwell Automation Publication 2198-UM001D-EN-P - May 2014
153
Chapter
8
Removing and Replacing Servo Drives
This chapter provides remove and replace procedures for Kinetix 5500 drives.
Before You Begin
When each drive is installed, network settings are configured from the setup
screens. Before removing the drive, revisit the Network menu and make note of
the static IP or DHCP settings. Refer to
access those settings.
You also need these tools available before you begin removal and replacement
procedures:
• Screwdrivers (to loosen/remove screws)
• Voltmeter (to make sure no voltage exists on drive connectors)
• Non-conductive probe for removing DC bus T-connectors
Topic
Page
Remove and Replace Kinetix 5500 Servo Drives
ATTENTION: This drive contains electrostatic discharge (ESD) sensitive parts
and assemblies. You are required to follow static-control precautions when you
install, test, service, or repair this assembly. If you do not follow ESD control
procedures, components can be damaged. If you are not familiar with static
control procedures, refer to Guarding Against Electrostatic Damage, publication
, or any other applicable ESD awareness handbook.
IMPORTANT
If you intend to use the same Logix Designer application after replacing your
drive, the new drive must be the same catalog number as the old drive.