Chapter 6 Review Unsupported Features and Implement Workarounds for Migration Issues

11. Double-click another ramp

button and select properties
for a right ramp button.

a. Set the Ramp down

Upper limit to 100.

Set the upper limit to the
number of set bit cursor
point objects on the
display.

b. Set the Ramp value to 1.

c. On the Label tab, set the

Image to Arrow Right

d. On the Connection tab,

set the Value connection
to the same tag in step 8.

12. Double-click another ramp

button and select properties
for an up ramp button.

a. Set the Ramp down

Lower limit to 1.

b. Set the Ramp value to the

last set bit cursor point
value on the row.

For example, if you have
four set bit cursor points
per row and five rows,
then the ramp value is 4.

In this example, if you
click the Up Ramp button
on the second row at
position 5, you would
expect it to ramp down
by 4, so the set bit cursor
point starts at the first set
bit cursor point on the
first row.

c. On the Label tab, set the

Image to Arrow Up.

d. On the Connection tab,

set the Value connection