Publication 2711P-QS001A-EN-P - October 2007

Chapter 4 Review the Application Conversion Log

converted
to memory tag, as its data type is not
supported.

Any PanelView ’e’ Remote I/O tags with these data types are
converted to HMI memory tags.

1 Digit BCD

2 Digit BCD

3 Digit BCD

5 Digit BCD

6 Digit BCD

7 Digit BCD

converted
to memory tag, as the "Bit Position"
data type is not supported.

If the data type of a PanelView ’e’ Remote I/O tag is bit
position but the address does not reference a single bit, the
tag is converted to an HMI memory tag.

converted
to memory tag, as its addresses
references an undefined rack.

If a PanelView ’e’ Remote I/O tag has an address with an
undefined rack, the tag is converted to an HMI memory tag.

converted
to memory tag, as its addresses is
invalid.

If a PanelView ’e’ Remote I/O tag does not have a valid I/O
address or block transfer address, the tag is converted to an
HMI memory tag.

Conversion Log Messages

Message

Applies to this
PanelBuilder 1400e object

Description