Review the Application Conversion Log Chapter 4

"Fixed Position" decimal point display
option not supported.
at on
.

Numeric Input Cursor Point

Numeric Data Display

The object has its Decimal Point Display option set to Fixed
Position.

FactoryTalk View ME software does not support an option to
display a decimal point in a numeric value. You can achieve the
same result using an expression.

For information on a workaround, refer to page 82.

"PLC Controlled" decimal point
display option not supported.
at on
.

Numeric Input Cursor Point

Numeric Data Display

The object has its Decimal Point Display option set to PLC
Controlled.

FactoryTalk View ME software does not support an option to
display a decimal point in a numeric value. You can achieve the
same result using an expression.

For information on a workaround, refer to page 81.

"Fixed Position" decimal point input
option not supported.
at on
.

Numeric Input Cursor Point

Numeric Keypad Enable

Numeric Keypad object

The object has its Decimal Point Input option set to Fixed
Position.

FactoryTalk View ME software does not support an option to
input a decimal point in a numeric value. You can achieve the
same result using an expression.

For information on a workaround, refer to page 82.

"PLC Controlled" decimal point input
option not supported.
at on
.

Numeric Input Cursor Point

Numeric Keypad Enable

Numeric Keypad

The object has its Decimal Point Input option set to PLC
Controlled.

FactoryTalk View ME software does not support an option to
input a decimal point in a numeric value. You can achieve the
same result using an expression.

For information on a workaround, refer to page 81.

"Decimal Key Controlled" decimal
point input option not supported.
at on
.

Numeric Input Cursor Point

Numeric Keypad Enable

Numeric Keypad

The object has its Decimal Point Input option set to Decimal
Key Controlled.

FactoryTalk View ME software does not support an option to
input a decimal point in a numeric value. You can achieve the
same result using an expression.

For information on a workaround, refer to page 81.

Numeric Keypad converted to a
Numeric Input Enable.
at on
.

Numeric Keypad

The display contains a Numeric Keypad object.

FactoryTalk View ME software does not support a Numeric
Keypad object so converts it to a Numeric Input Enable, which
needs to be configured.

Conversion Log Messages

Message

Applies to this
PanelBuilder 1400e object

Description