Page 49

background image

Publication 2711P-QS001A-EN-P - October 2007

49

Review Unsupported Features and Implement Workarounds for Migration Issues Chapter 6

3. Double-click the piloted

control list selector object to
open its properties.

4. In the Border style

pull-down list, select None
so when this object is
grouped it appears as a
single object.

5. In the Number of states

pull-down list, select the
number of states to match
the original PanelBuilder
1400e cursor list object.

6. Set the Back color to match

the background properties
of the original cursor list
object.

7. Set the Selection back color

to match the foreground
properties of the original
cursor list object.

8. Under Other, verify that all

boxes are unchecked.

9. Click the States tab.