beautypg.com

Rockwell Automation Migrating PanelView Enhanced Terminal Applications User Manual

Page 62

background image

62

Publication 2711P-QS001A-EN-P - October 2007

Chapter 6 Review Unsupported Features and Implement Workarounds for Migration Issues

9. Click the Connections tab.

The PanelBuilder 1400e
local message object list lets
you configure the number
of visible states. For each
visible state, you then
define an associated tag
connection.

Because FactoryTalk View
ME does not support a local
message object list, you
must assign each of the
‘Visible State x from PLC’
connections to a single local
message display. Create as
many displays as there are
visible states (messages).

10. Assign the ‘Visible State 1

from PLC’ associated tag to
the Value connection.

11. Click OK to accept changes.

12. Select the local message

display object and press
Ctrl+C to copy the object.

13. Press Ctrl+V to paste the

copied object.

14. Repeat steps 11 and 12 until

the number of pasted local
message displays matches
the number of visible states
(messages).

FactoryTalk View Object

Original PanelBuilder 1400e Object