Chapter 5
The Develop Menu
5 – 30
For DL10 or DL20
For DL50
20
20
10
The factory setting for the
Slave message length
attribute is 20, which
means the slave message length will always be set to 20 when you create a
message unless you have specified a new setting on the Message Attribute
Defaults menu.
Note: This attribute is not available from the DL40 message display onboard
editor. It is only accessible through the Offline Programming Software.
Echo relay to slave
The
Echo relay to slave
attribute sends the energize or de-energize relay
commands to the DL50 slave addressed in the
Send message to slave
number
attribute. These commands are sent in addition to any specified
message text.
After this attribute sends a relay command to the slave, the slave relay will
not de-energize until another message is sent to the slave that meets both of
the following conditions:
•
Energize relay
is set to No (to de-energize the relay)
•
Echo relay to slave
is set to Yes (to send a de-energize command to the
slave display)
Acceptable values for this attribute include:
For DL10 or DL20
For DL50
No
No
Yes
The factory setting for the
Echo relay to slave
attribute is No, which means
the
Echo relay to slave
attribute is always set to No when you create a
message unless you have specified a Yes on the Message Attribute Defaults
menu.
!
ATTENTION:
Use the slave relay for annunciator purposes
only. Do not use it for control.
Note: This attribute is not available from the DL40 message display onboard
editor. It is only accessible through the Offline Programming Software.