Chapter 5
The Develop Menu

5 – 30

For DL10 or DL20

For DL50

20

20

10

The factory setting for the

Slave message length

attribute is 20, which

means the slave message length will always be set to 20 when you create a
message unless you have specified a new setting on the Message Attribute
Defaults menu.

Note: This attribute is not available from the DL40 message display onboard
editor. It is only accessible through the Offline Programming Software.

Echo relay to slave

The

Echo relay to slave

attribute sends the energize or de-energize relay

commands to the DL50 slave addressed in the

Send message to slave

number

attribute. These commands are sent in addition to any specified

message text.

After this attribute sends a relay command to the slave, the slave relay will
not de-energize until another message is sent to the slave that meets both of
the following conditions:

Energize relay

is set to No (to de-energize the relay)

Echo relay to slave

is set to Yes (to send a de-energize command to the

slave display)

Acceptable values for this attribute include:

For DL10 or DL20

For DL50

No

No

Yes

The factory setting for the

Echo relay to slave

attribute is No, which means

the

Echo relay to slave

attribute is always set to No when you create a

message unless you have specified a Yes on the Message Attribute Defaults
menu.

!

ATTENTION:

Use the slave relay for annunciator purposes

only. Do not use it for control.

Note: This attribute is not available from the DL40 message display onboard
editor. It is only accessible through the Offline Programming Software.