Chapter 3
Installing the Software

3 – 9

10 If you are using the 1770-KF2 communications interface card, the

contents of the

CFG_KT.INI

file should be similar to the format shown in

the sample file below:

[DTL_KT.Options]
PATH=C:\ABIC\BIN

[DTL_DF1.1]
DEVICE=DF1
BAUD=9600
IRQ=4
COM_PORT=2
NAME=DTL_DF1
ERROR=1

PARITY=0

DUPLEX=1

0=BCC,1=CRC

0=No Parity, 1=Even Parity

③ 0=Half Duplex, 1=Full Duplex

11 Save the file. If you are using the DOS text editor, type:

[ALT]FXY

If you are using an Ethernet link and want to enable PLC PassThrough file
transfers, you must first modify your

CONFIG.SYS

and

AUTOEXEC.BAT

files, and install and configure the following products on your PC:

Allen-Bradley Ethernet communications interface card (Cat. Nos.
6628-A5 or -A7) or equivalent

FTP’s PC/TCP Software for DOS/Windows (FTP Cat. No. PC-210)

Install Ethernet Card

Follow the instructions that came with your Allen-Bradley Ethernet
communications interface card to install and configure it on your personal
computer.

Install the PC/TCP Software

Follow the instructions that came with FTP’s PC/TCP Software to install it
on your personal computer.

Install the Offline Programming Software

Perform the basic installation procedure described earlier in this chapter to
install the Offline Programming Software on your personal computer.

Installing the Software for
Ethernet PLC PassThrough