background image

Chapter 5
The Develop Menu

5 – 29

Note: When used with

[CTRL][X]

(ASCII Input Data), the underscore

prompt for this data will still be displayed on the DL40 message display even
when

Hide message on display

is active.

Select

Yes

to activate or

No

to deactivate.

Acknowledge message

Enabling this attribute will instruct the DL40 message display to hold the
message until you press the

[MSG ACK]

button on the front of the DL40

display. The next message will be displayed only after the

[MSG ACK]

button has been pushed.

Note: We recommend that you enable message queueing (from the

Options

menu) when using

Acknowledge message

attribute.

Select

Yes

to activate or

No

to deactivate.

Slave message color

This attribute allows you to control the color of a message sent to a
color-capable slave display such as the Dataliner DL50 Tri-Color Marquee
Display. The setting options available to you include:

For DL10 or DL20

For red DL50

For color DL50

Default

Default

Default

Red

Green

Amber

Important: The factory setting for this attribute in the Message Attribute

Defaults menu is

Default

. We recommend leaving that value

unchanged. Do not use any selection other than

Default

for

DL10, DL20, or Red DL50 slave displays.

Note: This attribute is not available from the DL40 message display onboard
editor. It is only accessible through the Offline Programming Software.

Slave message length

Use the

Slave message length

attribute only with DL50 slave displays. Its

purpose is to allow display of 10-character messages on “short” DL50
displays operating in large text mode. Large text mode displays characters
that are 4.8 in. (12.2 cm) tall. Applicable displays include Catalog No.
2706-F11J (Red DL50 Message Display) and 2706-F11JC (Tri–color capable
DL50 Message Display).

Acceptable values for this attribute include: