Rockwell Automation 1747-BSN Backup Scanner Module User Manual
Page 91

Publication 1747-UM010B-EN-P - September 2003
Configuration and Programming 5-29
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1
1
x
x
x
x
x
x
x
x
x
x
x
x
x
x
1
0
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
1
1
0
0
1
0
0
0
0
1
0
0
0
1
0
0
1
0
0
1
1
1
1
1
0
1
1
0
0
1
1
1
1
0
0
1
1
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
0
1
1
0
0
1
0
0
0
0
1
0
0
0
1
0
0
1
0
0
1
1
1
1
1
0
1
1
0
0
1
1
1
0
2
4
6
0
2
4
6
0
2
4
6
0
2
4
6
M1 (Status) File Primary/Normal
RIO Logical Rack 3 RIO Logical Rack 2
RIO Logical Rack 1
RIO Logical Rack 0
e = slot number of the SLC rack containing the scanner x =
not used/defined
G File
RIO Logical Rack 3
Starting Group
RIO Logical Rack 2
Starting Group
RIO Logical Rack 1
Starting Group
RIO Logical Rack 0
Starting Group
Primary Device Address, Word 8
Primary Device Size, Word 9
Primary Active Device Status, Word 10
M1:e.3
M1:e.4
M1:e.5
Logical Rack 0 Device Fault Status Word 12
Logical Rack 1 Device Fault Status Word 13
Logical Rack 2 Device Fault Status Word 14
Logical Rack 3 Device Fault Status Word 15
M1:e.12
M1:e.13
M1:e.14
M1:e.15
Status Word, Word 0
Baud Rate, Word 2
Primary Logical Device Address, Word 1
Primary Logical Image Size, Word 2
M1 File
M1:e.0
M1:e.2
Bit Number (decimal)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1
1
x
x
x
x
x
x
x
x
x
x
x
x
x
x
1
0
x
x
x
x
x
x
x
x
x
x
x
x
x
x
0
0
0
0
x
x
x
x
x
x
x
x
0
0
0
0
x
x
x
x
x
x
x
x
0
0
0
0
x
x
x
x
x
x
x
x
0
1
1
1
x
x
x
x
x
x
x
x
1
1
0
0
1
0
0
0
0
1
0
0
0
1
0
0
1
0
0
1
1
1
1
1
0
1
1
0
0
1
1
1
1
0
0
1
1
0
0
0
0
1
0
0
0
0
0
0
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
1
1
0
0
1
0
0
0
0
1
0
0
0
1
0
0
1
0
0
1
1
1
1
1
0
1
1
0
0
1
1
1
0
2
4
6
0
2
4
6
0
2
4
6
0
2
4
6
M1 (Status) File Complementary
RIO Logical Rack 11
RIO Logical Rack 10
RIO Logical Rack 9
RIO Logical Rack 8
e = slot number of the SLC rack containing the scanner x = not used/defined
G File
RIO Logical Rack 11
Starting Group
RIO Logical Rack 10
Starting Group
RIO Logical Rack 9
Starting Group
RIO Logical Rack 8
Starting Group
Primary Device Address, Word 3
Primary Device Size, Word 4
Primary Active Device Status, Word 5
M1:e.3
M1:e.4
M1:e.5
Logical Rack 0 Device Fault Status Word 12
Logical Rack 1 Device Fault Status Word 13
Logical Rack 2 Device Fault Status Word 14
Logical Rack 3 Device Fault Status Word 15
M1:e.12
M1:e.13
M1:e.14
M1:e.15
Status Word, Word 0
Baud Rate, Word 2
Complementary Logical Device Address, Word 3
Complementary Logical Image Size, Word 4
M1 File
M1:e.0
M1:e.2
Bit Number (decimal)
IMPORTANT
Individual quarter logical racks within a device
cannot be faulted. Therefore, only the starting logical
group of the device needs to be monitored.