Controllogix system communications, Hardware specifications – Rockwell Automation 1756-HIST2G Historian ME 2.1 User Manual
Page 20
F
ACTORY
T
ALK
H
ISTORIAN
ME M
ODULE
U
SER
’
S
G
UIDE
10
ControlLogix System Communications
A ControlLogix system consists of anything from your FactoryTalk Historian ME
and a stand-alone controller in a single chassis to more complex configurations that
include Ethernet/IP communication modules. The ControlLogix system in a chassis
uses connections to establish communication links between devices such as a
Logix5000 controller-to-local communication modules such as an EN2T or ENBT
module. RSLogix™ 5000 programming software and RSLinx Classic™ software are
used to facilitate communication and connections in the ControlLogix system.
Hardware Specifications
Refer to the “Hardware Specifications” appendix for a summary of hardware
specifications.
ControlLogix System Communication Applications
RSLogix 5000
Without AOP:
V13 - V17
With AOP:
V16, V17
A programming software for Logix5000
controllers.
The FactoryTalk Historian ME Add On
Profile (AOP) is a RSLogix 5000 module
profile that allows FactoryTalk Historian
ME users to perform operations such as
tag monitoring, module shutdown, and
module restart without using the
FactoryTalk Historian ME web interface.
Refer to the “RSLogix 5000 Add-on
Profile” appendix for information about
using AOP.
RSLinx Classic
V2.55
A communications software that provides
an easy way to upload and download
Ladder logic files from Logix5000
controllers.
RSLogix 5000 uses RSLinx Classic to
browse your controller.