Manually Transferring Points

To map data points to the FactoryTalk Historian SE server, select the points in the

table by checking the checkboxes, and click [Save]. To confirm the points have been

mapped to the FactoryTalk Historian SE, click [Search]. The points you selected for
mapping should have a Y in the Created in SE column.

After transferring the data, you can perform a search in FactoryTalk Historian SE

[using the FactoryTalk Historian SE System Management Tool (SMT)] to verify the

points have been mapped to the FactoryTalk Historian SE.

Removing Points from Data Transfer

If you no longer want to transfer data for a point or points, clear the checkbox in the

table for those points. Note that this only removes them from the Data Transfer

service. To remove the points from FactoryTalk Historian SE, and thereby free up

license space, you must delete the points in FactoryTalk Historian SE.

The "FTMS" Available Points value may not update immediately because it takes
approximately fifteen minutes to update the FactoryTalk Historian SE server.