beautypg.com

Restoring the module name – Rockwell Automation 1756-HIST2G Historian ME 2.1  User Manual

Page 151

background image

8 • A

DMINISTERING

THE

M

ODULE

141

Restoring the Module Name

When restoring a module, make sure that the restored module’s name is the same as

the original module’s name. When tags are transferred to FactoryTalk Historian SE,

the tags are appended with the module name. If the restored module’s name is

different, the same tags will be transferred again with a different name.
For example:

Tags from the module FTHME1 are being transferred to FactoryTalk Historian

SE. When transferred, the module name is added to the tag name (e.g.,

FTHME1.<tag_name>).

FTHME1 is backed up and restored. However, the module name is now

FTHME2. The same tags that were already transferred will be transferred again

because now their tag name is FTHME2.<tag_name>. These duplicate tags will

be counted against your allotted number of points.

To avoid this issue, ensure that the restored module’s name is correct after the

restoration process. Click Advanced in the main navigation bar, and then click
System Settings

in the left navigation bar to view the module name.

1. Select the backup file and click [Select].
2. When the configuration table displays, click [Continue]

This manual is related to the following products: