3 aif1out, Function library, Aif1out – Lenze ECSCSxxx User Manual
Page 251

Function library
AIF1Out
l
251
EDBCSXS064 EN 4.0
12.3
AIF1Out
Function
This function block provides the interface for output signals (e. g. setpoint and actual
values) to the attached fieldbus module.
,
Please read the documentation for the connected fieldbus module.
AIF1Out
Byte
1
Byte
2
Byte
3
Byte
4
Byte
5
Byte
6
Byte
7
Byte
8
C6130/1
C6130/2
C6130/4
C6150/1
C6130/3
C6110/1
C6110/16
16 Bit
LowWord
16 Bit
HighWord
16 Bit
LowWord
16 Bit
HighWord
16 Bit
16 Bit
16 Bit
16 binary
signals
16 Bit
16 binary
signals
C6154
C6131/1
C6131/2
C6131/3
C6111/1
C6111/16
C6131/4
C6151/1
X1
0
0
0
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
…
…
…
AIF1Out-DctrlStat
AIF1Out-W1
AIF1Out-W1
AIF1Out-W2
AIF1Out-W2
AIF1Out-Bit0
AIF1Out-Bit0
AIF1Out-Bit15
AIF1Out-Bit15
AIF1Out-W3
AIF1Out-W3
AIF1Out-Bit0
AIF1Out-Bit15
…
AIF1Out-W2/W3
AIF1Out-W2/W3
ECSXA202
Fig. 12−3
AIF1Out function block