Appendix, Code table – Lenze ECSCSxxx User Manual
Page 370

Appendix
Code table
l
370
EDBCSXS064 EN 4.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
[C0095] Rotor pos adj
0
Activation of rotor position
adjustment for automatic
determination of the rotor
displacement angle.
C0058 displays the determined
rotor displacement angle (offset
angle).
^ 151
0
Inactive
1
Active
C0096
Extended password protection
for bus systems with activated
password (C0094)
All codes in the user menu can be
accessed.
1 AIF/CAN prot.
0
No access protection
AIF access protection
2 AIF/CAN prot.
0
No access protection
CAN access protection
0
No access protection
Full access
1
Read protection
Reading not possible
2
Write protection
Writing not possible
3
Read/write protection
Reading and writing not possible
C0097 DIS:Lt−Ident
0
Power stage identification
0
{1}
255
C0098 Set position
0
Home position of encoder
−2147483647
{1 inc}
2147483647
C0099 S/W version
Firmware version
Read only
0,0
{0,1}
25,5
C0101
15 additional acceleration times
for the speed setpoint.
Can be retrieved via digital
signals SPEED−NSET.TIx.
^ 327
1 add Tir
0.000
0.000
{0.001 s}
999.999 Relating to speed variation
0 rpm ... n
max
(C0011)
2 add Tir
0.000
... add Tir
0.000
14 add Tir
0.000
15 add Tir
0.000
C0103 add Tif
15 additional deceleration times
for the speed setpoint.
Can be retrieved via digital
signals SPEED−NSET.TIx.
^ 327
1 add Tif
0.000
0.000
{0.001 s}
999.999 Relating to speed variation
0 rpm ... n
max
(C0011)
2 add Tif
0.000
...
0.000
14 add Tif
0.000
15 add Tif
0.000
C0105 QSP Tif
0.0
Deceleration time for quick stop
(QSP)
^ 297
^ 144
0.000
{0.001 s}
999.999 Relating to speed variation n
max
(C0011) ...0 rev./min.