Appendix – Lenze ECSCSxxx User Manual
Page 394

Appendix
Code table
l
394
EDBCSXS064 EN 4.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C0605 MONIT OH5
2
Fault response − monitoring of
temperature inside the
controller.
Temperature threshold can be
set under C0124.
^ 205
0
TRIP
2
Warning
3
Off
C0606 MONIT OC8
2
Fault response − monitoring of
I
2
x t motor utilisation.
Threshold can be set under
C0120.
^ 210
0
TRIP
2
Warning
3
Off
C0607 MONIT NMAX
0
Fault response − maximum speed
monitoring of the machine
0
TRIP
2
Warning
3
Off
C0608 ovr. Tx−Queue
2
Fault response − transmission
memory overflow of free CAN
objects
0
TRIP
1
Message
2
Warning
3
Off
4
FAIL−QSP
C0745
Only the Lenze service is allowed
to make changes!
Oscilloscope − internal service
C0746
Only the Lenze service is allowed
to make changes!
Oscilloscope − internal service
1
...
24
C0747
Only the Lenze service is allowed
to make changes!
Oscilloscope − internal service
C0855
Digital process data input words
are indicated on the AIF interface
(AIF1_IN)
Hexadecimal value is bit−coded.
Read only
^ 248
1 AIF1 IN bits
0000
{hex}
FFFF Input word 2 (bit 0 ... 15)
2 AIF1 IN bits
Input word 3 (bit 0 ... 15)