Commissioning
Configuring the digital inputs and outputs
Change of the terminal assignment
l
123
EDBCSXS064 EN 4.0
Code
Possible settings
IMPORTANT
No.
Designation
Lenze/
{Appl.}
Selection
C3005 ControlMode
0
Selection of operating modes
^ 126
0
Common
Display with changed standard
application
100
None
Reset of all signal connections
1000
SpeedTerm
Speed−controlled, setpoint via
analog input
^ 318
1003
SpeedAIF
Speed−controlled, setpoint via
AIF
1005
SpeedCAN
Speed−controlled, setpoint via
MotionBus (CAN)
4000
TorqueTerm
Torque−controlled, setpoint via
analog input
^ 343
4003
TorqueAIF
Torque−controlled, setpoint via
AIF
4005
TorqueCAN
Torque−controlled, setpoint via
MotionBus (CAN)
[C6371]
Selection of the digital output
signals for the digital output and
the brake relay
^ 308
1 DigoutIn−dig
1000
0 (FALSE, not assigned)
Source for the output signal at
the digital output X6/DO1
(DigOut−Out1)
2 DigoutIn−dig
1000
0 (FALSE, not assigned)
Source for the control of the
brake relay (DigOut relay)
For possible signals see "selection list − digital
signals"
^ 428