5 aif2out, Function library, Aif2out – Lenze ECSCSxxx User Manual
Page 258: Codes

Function library
AIF2Out
l
258
EDBCSXS064 EN 4.0
12.5
AIF2Out
Function
This function block provides the interface for output signals (e. g. setpoint and actual
values) to the attached fieldbus module.
,
Please read the documentation for the connected fieldbus module.
Byte
1
Byte
2
Byte
3
Byte
4
Byte
5
Byte
6
Byte
7
Byte
8
16 Bit
LowWord
16 Bit
HighWord
16 Bit
16 Bit
16 Bit
16 Bit
C6155
0
0
1
1
C6151/2
C6131/6
C6131/7
C6131/8
C6131/5
AIF2Out
C6130/6
C6130/7
C6130/8
C6150/2
C6130/5
X1
AIF2Out-W1
AIF2Out-W0
AIF2Out-W3
AIF2Out-W0/W1
AIF2Out-W2
ECSXA204
Fig. 12−5
AIF2Out function block
Codes
Code
Possible settings
IMPORTANT
No.
Designation
Lenze/
{Appl.}
Selection
C6130
Display of the analog output
signals to the fieldbus module
−32768
{1}
32767
1 AIF−AnOut
Output word AIF1Out−DctrlStat
^ 251
2 AIF−AnOut
Output word AIF1Out−W1
3 AIF−AnOut
Output word AIF1Out−W2
4 AIF−AnOut
Output word AIF1Out−W3
5 AIF−AnOut
Output word AIF2Out−W0
^ 258
6 AIF−AnOut
Output word AIF2Out−W1
7 AIF−AnOut
Output word AIF2Out−W2
8 AIF−AnOut
Output word AIF2Out−W3
9 AIF−AnOut
Output word AIF3Out−W0
^ 263
10 AIF−AnOut
Output word AIF3Out−W1
11 AIF−AnOut
Output word AIF3Out−W2
12 AIF−AnOut