Code table
l
366
EDBCSXS064 EN 4.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C0040 Ctrl enable
1
Controller enable / controller
inhibit (CINH)
l
Writing: Controls the
controller inhibit
l
Reading: Reads the status of
the controller inhibit
0
Controller inhibited
1
Controller enabled
C0042 DIS: QSP
Quick stop status (QSP)
Only display
^ 297
^ 144
0
QSP not active
1
QSP active
C0043 Trip reset
0
Reset active fault message
(TRIP−RESET)
^ 246
0
Reset fault message (TRIP−RESET) / no
fault
1
Active fault message
C0050 MCTRL−NSET2
Speed setpoint on speed
controller input
(MCTRL_nNSetIn_a)
Read only
−100,00
{0.01 %}
100.00
C0051 MCTRL−NACT
Actual speed (MCTRL_nNAct_a)
Read only
−30000
{1 rpm}
30000
C0052 MCTRL Umot
Actual motor voltage
Read only
0
{1 V}
800
C0053 UG−VOLTAGE
DC−bus voltage
Read only
0
{1 V}
900
C0054 Imot
Actual motor current
Read only
0,0
{0.1 A}
500,0
C0055 Phase current
Motor phase current
Read only
1 iu
0,0
{0.1 A}
500,0 Actual current in U phase
2 iv
Actual current in V phase
3 iw
Actual current in W phase
4 Io
Actual theoretical star−point
current
C0056 MCTRL−MSET2
Torque setpoint on speed
controller output
(MCTRL_nMSetIn_a)
Read only
−100
{1 %}
100
C0057 Max Torque
Maximum possible torque of the
drive configuration
Dependent on C0022, C0081,
C0087, C0088
Read only
0,0
{0.1 Nm}
500,0