Commissioning, Direction of rotation / quick stop (qsp), Holding brake – Lenze ECSCSxxx User Manual
Page 129: Analog input voltage supply, Switch for controller enable/inhibit, Motor system cable, Voltage supply of motor holding brake, Voltage supply of control, Controller enable, System cable feedback

Commissioning
Selecting the operating mode/control structure
Speed control with setpoint via analog input
l
129
EDBCSXS064 EN 4.0
L1
+UG
BR1
T1
DO1
B1
U
W
CH
CAH
CH
L2
-UG
+UG
+UG
BR0
T2
DI1
B2
V
PE
CL
CAL
CL
L3
-UG
+UG
DI1
DI2
CG
CAG
CG
PE
PE
-UG
PE
PE
DI2
DI3
PE
PE
DO1
DI4
CH
CH
+24
V
AI-
GND
CG
CG
D24
AI+
+24
V
CL
CL
GND
AG
SO
SI1
SI2
B+
B-
S24
PE
PE
X21
X23
X22
ECSxE...
ECSxA...
X6
X6
X25
X24
X7
X8
X4
X14
X4
K1
L1
L2
L3
N
PE
F4
F1
F2
F3
Z1
PES
PES
PES
PES
PES
PES
PES
PES
PES
PES
Off
On
K1
K1
K1
+
+
-
-
+
-
M
3~
R
J
6
2
0 2
1 3
4
7
5
6
9
+24 VDC
GND
:
;
<
F
1
,6
A
ECSXA280
Fig. 6−10
Connection diagram for configuration 1000 (setpoint via analog input)
0
Direction of rotation / quick stop (QSP)
1
Direction of rotation / quick stop (QSP)
2
Fixed speed C0039/1
3
Holding brake
4
Analog input voltage supply
5
Switch for controller enable/inhibit
6
Motor system cable
7
Voltage supply of motor holding brake
9
Voltage supply of control
:
Controller enable
;
System cable feedback
<
DC−bus voltage
HF shield termination by large−surface PE connection
Twisted cables
)
Note!
In the wiring example (Fig. 6−10) a HIGH level is fixedly applied on X6/SI2
(pulses for power section enabled).