Code initialisation values
Unlike the initialisation values for the default setting, the following codes are initialised via the
project
Code Default
setting Comment
C0425/000
6
DFIN number of increments 16384 inc/rev.
C0428/000
1
Touch-probe via
digital input X5/E5 (DFIN)
C0911/000
0
Touch-probe via zero pulse (MCTRL)
C2104/000
1
Auto-start after mains power-up
C4010/002
1,0000
Control bit 1 is read from input bit 1
C4010/003
2,0000
Control bit 2 is read from input bit 2
C4010/004
3,0000
Control bit 3 is read from input bit 3
C4010/005
4,0000
Control bit 4 is read from input bit 4
C4010/006
5,0000
Control bit 5 is read from input bit 5
C4010/007
6,0000
Control bit 6 is read from input bit 6
C4010/008
7,0000
Control bit 7 is read from input bit 7
C4010/009
8,0000
Control bit 8 is read from input bit 8
C4010/010
9,0000
Control bit 9 is read from input bit 9
C4010/011
10,0000
Control bit 10 is read from input bit 10
C4010/012
11,0000
Control bit 11 is read from input bit 11
C4010/013
12,0000
Control bit 12 is read from input bit 12
C4010/014
13,0000
Control bit 13 is read from input bit 13
C4010/015
14,0000
Control bit 14 is read from input bit 14
C4010/016
15,0000
Control bit 15 is read from input bit 15
C4010/017
16,0000
Control bit 16 is read from input bit 16
C4010/018
17,0000
Control bit 17 is read from input bit 17
C4010/019
18,0000
Control bit 18 is read from input bit 18
C4010/020
19,0000
Control bit 19 is read from input bit 19
C4010/021
20,0000
Control bit 20 is read from input bit 20
C4010/022
21,0000
Control bit 21 is read from input bit 21
C4010/023
22,0000
Control bit 22 is read from input bit 22
C4010/024
23,0000
Control bit 23 is read from input bit 23
C4010/025
24,0000
Control bit 24 is read from input bit 24
C4010/026
25,0000
Control bit 25 is read from input bit 25
C4010/027
26,0000
Control bit 26 is read from input bit 26
C4010/028
27,0000
Control bit 27 is read from input bit 27
C4010/029
28,0000
Control bit 28 is read from input bit 28
C4010/030
29,0000
Control bit 29 is read from input bit 29
C4010/031
30,0000
Control bit 30 is read from input bit 30
C4010/032
31,0000
Control bit 31 is read from input bit 31