Prepared Solution Servo PLC / ECSxA 1.1 EN
11-4
11.2.4 VarInterfaceFlyingSaw
Global variables
(Variable type: VAR_GLOBAL)
Identifier Data
type
Value/meaning
g_bDriveReady
BOOL
Drive ready signal
g_bStartHoming BOOL Start
homing
g_bHomingMark BOOL Homing
cam
g_bManualJogPos
BOOL
Inching in positive direction
g_bManualJogNeg
BOOL
Inching in negative direction
g_bStartPositioningHome
BOOL
Move to initial position
g_bAutomatic
BOOL
Start automatic operation
g_bCutReady
BOOL
Cut done signal
g_bHeadCut
BOOL
Trigger top cut
g_bStartGap
BOOL
Make gap in the material
g_bTPUnrealised
BOOL
Mark not detected during mark control
g_bMarkenSync
BOOL
Activate mark synchronisation
g_bModusSynchronize BOOL
Synchronisation
mode
g_bTripReset BOOL Reset
error
g_bTripresetMultiPlex BOOL
Reset error using multiplexer
g_bUserTripSet
BOOL
Set user error
g_bImperialUnits
BOOL
Switch between imperial and metric measuring system
g_nSimulationFrequency INT
Simulation
speed
g_bSelInputFrequency
BOOL
Switch between DFIN and simulation
g_dnFollowErrorLimt DINT
Following
error
limit
g_bHomePositionAvailable
BOOL
Home position known
g_bGapStatus
BOOL
Gap made in the material
g_bAxisSynchron BOOL
Axis synchronised signal
g_wActualFaultNumber
WORD
Actual error number
g_bHomingBusy
BOOL
Homing is active
g_bPosBusy
BOOL
Positioning is active
g_bDoubleLength
BOOL
Double length detected
g_dnActPosFlyingSaw
DINT
Actual position of the axis
g_byCtrlMode BYTE Multiplexer
mode
g_nFiltering
INT
Master speed filtering
g_dwTiFlyingSaw
DWORD
Flying saw acceleration time
g_dwTifFlyingSaw DWORD Flying saw deceleration time
g_dnOffsetTP
DINT
Distance between mark detection and the initial position
g_bSoftwareLimitsActive
BOOL
Software limit switches active
g_bCutCounterUP_NOK_Multi BOOL