Function library
Function blocks
3.2.7
AND operation (AND)
3−26
l
EDSVS9332S−EXT EN 2.0
A N D 6
&
A N D 6 - I N 1
A N D 6 - I N 2
A N D 6 - I N 3
A N D 6 - O U T
C 1 1 7 6 / 1
C 1 1 7 6 / 2
C 1 1 7 6 / 3
C 1 1 7 5 / 1
C 1 1 7 5 / 2
C 1 1 7 5 / 3
Fig. 3−18
AND operation (AND6)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
AND6−IN1
d
C1176/1
bin
C1175/1
2
1000
−
AND6−IN2
d
C1176/2
bin
C1175/2
2
1000
−
AND6−IN3
d
C1176/3
bin
C1175/3
2
1000
−
AND6−OUT
d
−
−
−
−
−
−
A N D 7
&
A N D 7 - I N 1
A N D 7 - I N 2
A N D 7 - I N 3
A N D 7 - O U T
C 1 1 7 9 / 1
C 1 1 7 9 / 2
C 1 1 7 9 / 3
C 1 1 7 8 / 1
C 1 1 7 8 / 2
C 1 1 7 8 / 3
Fig. 3−19
AND operation (AND7)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
AND7−IN1
d
C1179/1
bin
C1178/1
2
1000
−
AND7−IN2
d
C1179/2
bin
C1178/2
2
1000
−
AND7−IN3
d
C1179/3
bin
C1178/3
2
1000
−
AND7−OUT
d
−
−
−
−
−
−