43 motor potentiometer (mpot), Motor potentiometer (mpot), Function library – Lenze EVS9332xS User Manual
Page 177: Function blocks

Function library
Function blocks
3.2.43
Motor potentiometer (MPOT)
3−125
l
EDSVS9332S−EXT EN 2.0
3.2.43
Motor potentiometer (MPOT)
Purpose
The FB replaces a hardware motor potentiometer.
The motor potentiometer is used as an alternative setpoint source, which is controlled via two
terminals.
C0260
C0262
MPOT1
MPOT1-OUT
MPOT
CRTL
C0269/1
C0269/2
C0269/3
MPOT1-DOWN
MPOT1-INACT
MPOT1-UP
C0264
C0263
C0261
C0267/1
C0268
C0267/2
C0265
Fig. 3−107
Motor potentiometer (MPOT1)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
MPOT1−UP
d
C0269/1
bin
C0267/1
2
1000
−
MPOT1−INACT
d
C0269/3
bin
C0268
2
1000
−
MPOT1−DOWN
d
C0269/2
bin
C0267/2
2
1000
−
MPOT1−OUT
a
−
−
−
−
−
Function
Control of the motor potentiometer:
l
MPOT1−UP = HIGH
– The motor potentiometer approaches its upper limit value.
l
MPOT1−DOWN = HIGH
– The motor potentiometer approaches its lower limit value.
l
MPOT1−UP = LOW and MPOT1−DOWN = LOW or
MPOT1−UP = HIGH and MPOT1−DOWN = HIGH:
– The motor potentiometer does not change the output signal.