Application examples – Lenze EVS9332xS User Manual
Page 252

Application examples
4.6
Master frequency cascade − slave − drive (C0005 = 7000)
4−14
l
EDSVS9332S−EXT EN 2.0
4.6
Master frequency cascade − slave − drive (C0005 = 7000)
Tip!
The most important settings can be found in the menu: "Short Setup / Speed mode" of the operating
module or in the menu "Short setup / Speed mode" in Global Drive Control.
Enter motor type (contains all nameplate data of the motor)
C0173
xxx
Enter UG limit (mains voltage)
C0086
000
Enter motor data manually
Enter maximum motor current
C0022 xxxA Determine
Imax
Enter controller configuration
C0005
7000
Select digital frequency cascade − slave
Speed setpoint settings
C0011
xxx rpm
Determine max. speed
C0032
xxx
Numerator of gearbox factor
C0033
xxx
Denominator of gearbox factor
C0425
xxx
Adjust encoder constant to the master
C0473/1
xxx
Numerator of stretching factor
C0533
xxx
Denominator of stretching factor
Application parameters
C0070
xxx
Vp n−controller
C0071
xxx
Tn n−controller
C0254
xxx
Gain of the angle controller
Save parameters
C0003
xxx
Save all parameters