34 freely assignable input variables (fevan), Freely assignable input variables (fevan), Function library – Lenze EVS9332xS User Manual
Page 142: Function blocks

Function library
Function blocks
3.2.34
Freely assignable input variables (FEVAN)
3−90
l
EDSVS9332S−EXT EN 2.0
3.2.34
Freely assignable input variables (FEVAN)
Purpose
Transfer of analog signals to any code. At the same time, the FB converts the signal into the data
format of the target code.
F E V A N 1 - I N
C 1 0 9 8
C 1 0 9 6
C 1 0 9 3
C 1 0 9 4
C T R L
+
+
C 1 0 9 5
S & H
C 1 0 9 9
F E V A N 1 - L O A D
C 1 0 9 7
C 1 0 9 0
C o d e / S u b c o d e
( C x x x x / y y y )
C 1 0 9 2
C 1 0 9 1
F E V A N 1 - B U S Y
F E V A N 1 - F A I L
F E V A N 1
Fig. 3−84
Freely assignable input variables (FEVAN1)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
FEVAN1−IN
a
C1098
dec
C1096
1
Input value
FEVAN1−LOAD
d
C1099/1
bin
C1097/1
2
A LOW−HIGH edge transmits the converted signal to the
target code.
FEVAN1−BUSY
d
−
−
−
−
HIGH = transmitting
FEVAN1−FAIL
d
−
−
−
−
HIGH = transmission failed
A LOW−HIGH edge at FEFAN1−LOAD sets FEFAN1−FAIL
= LOW.
−
−
C1090
−
−
−
Display of the converted signal
F E V A N 2 - I N
C 1 5 0 8
C 1 5 0 6
C 1 5 0 3
C 1 5 0 4
C T R L
+
+
C 1 5 0 5
S & H
C 1 5 0 9
F E V A N 2 - L O A D
C 1 5 0 7
C 1 5 0 0
C o d e / S u b c o d e
( C x x x x / y y y )
C 1 5 0 2
C 1 5 0 1
F E V A N 2 - B U S Y
F E V A N 2 - F A I L
F E V A N 2
Fig. 3−85
Freely assignable input variables (FEVAN2)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
FEVAN2−IN
a
C1508
dec
C1506
1
Input value
FEVAN2−LOAD
d
C1509/1
bin
C1507/1
2
A LOW−HIGH edge transmits the converted signal to the
target code.
FEVAN2−BUSY
d
−
−
−
−
HIGH = transmitting
FEVAN2−FAIL
d
−
−
−
−
HIGH = transmission failed
A LOW−HIGH edge at FEFAN2−LOAD sets FEFAN2−FAIL
= LOW.
−
−
C1500
−
−
−