Configuration, Basic configurations – Lenze EVS9332xS User Manual
Page 31

Configuration
Basic configurations
2.2.4
Master frequency coupling
2−19
l
EDSVS9332S−EXT EN 2.0
Features
The features describe the basic properties of this configuration. Some of them, however, can only
be used by reprogramming.
l
Hardware connection of the master frequency input with the master frequency output (so that
any number of drives can be connected in series)
l
Setpoint evaluation with a factor (numerator/denominator) for the corresponding slave
(gearbox adaptation). Can be set via an analog signal source:
– Terminal,
– code or
– function block.
l
external torque limitation is possible
l
QSP function for the individual drive. The setpoint is continued to be output.
l
CINH function for the individual drive. The setpoint is continued to be output to the master
frequency output.
l
Possible interventions for phase trimming and speed correction via
– LECOM
– analog terminal
– one of the signal sources (function blocks)
l
Message "following error limit reached" can be set via code
l
TRIP when reaching the phase controller limit
l
Speed limit of slave 0 = C0011
l
Phase controller influence can be set and switched off via the digital input
l
Homing function is possible via zero track or touch probe
l
Synchronising to a setpoint is possible via zero track or touch probe
l
Synchronising characteristic can be set via ramp−function generator