Function library, Working with function blocks, 3 connecting function blocks – Lenze EVS9332xS User Manual
Page 59: Condition: – default setting

Function library
Working with function blocks
3.1.3
Connecting function blocks
3−7
l
EDSVS9332S−EXT EN 2.0
Basic procedure
1. Select the configuration code of the function block input which is to be changed.
2. Determine the source of the input signal for the selected input
(e.g. from the output of another function block).
3. The function block input is assigned via a menu which contains only those signal sources
which are of the same type as the function block input to be assigned.
4. Select and confirm the signal source.
5. Remove undesired connections, if any.
– For this, select the corresponding signal assignment of the input via the configuration code
(e.g. FIXED0, FIXED1, FIXED0%, ...).
6. Repeat 1. to 5. until the desired configuration is set.
7. Save modified configuration in the desired parameter set.
Example
l
Condition:
– Default setting
l
Task:
– Square the analog signal of X6/3, X6/4 and output to X6/62.
l
Solution:
– You need the function blocks AIN2, ARIT2 and AOUT2.
+ −
*
/
x/(1−y)
C0600
x
y
ARIT2
ARIT2−OUT
C0602/1
"200%
C0602/2
ARIT2−IN1
ARIT2−IN2
C0601/1
C0601/2
62
AOUT1
C434/1
+
+
AOUT1−IN
AOUT1−GAIN
AOUT1−OFFSET
C0434/3
C0434/2
C0431
C0433
C0432
3
4
AIN2
+
+
AIN2−OUT
AIN2−GAIN
AIN2−OFFSET
C0409/1
C0409/2
C0407
C0408
C0108/1
C0109/1
C0027/2
C0026/2
Fig. 3−3
Example of a simple configuration