Quick stop, Ramp function generator stop, Function library – Lenze EVS9332xS User Manual
Page 123: Function blocks

Function library
Function blocks
3.2.26
Digital frequency ramp function generator (DFRFG)
3−71
l
EDSVS9332S−EXT EN 2.0
3.2.26.2
Quick stop
Removes the drive from the network and brakes it to standstill.
l
Activate with DFRFG−QSP = HIGH.
l
Set deceleration time via C0753.
l
Store the setpoint phase detected at DFRFG−IN.
l
Approach the setpoint phase via the profile generator after resetting the quick stop request.
t
DFRFG-IN
C0752
C0751
C0751
DFRFG-QSP
t
DFRFG-OUT
C0753
Fig. 3−68
Quick stop DFRFG
3.2.26.3
Ramp function generator stop
Maintains the state of the profile generator during operation.
l
Activate with DFRFG−STOP = HIGH
l
Output of the last state at DFRFG−OUT.
l
Store the setpoint phase detected at DFRFG−IN.
l
Approach the setpoint phase via the profile generator after resetting the stop request.
t
DFRFG-IN
C0752
DFRFG-STOP
t
DFRFG-OUT
Fig. 3−69
Ramp function generator stop