Function library, Function blocks, 34 freely assignable input variables (fevan) – Lenze EVS9332xS User Manual
Page 143: Function, Data transmission, Transmission errors may occur if, No target code is available, No target subcode is available

Function library
Function blocks
3.2.34
Freely assignable input variables (FEVAN)
3−91
l
EDSVS9332S−EXT EN 2.0
Function
l
Conversion of the read data via:
– Numerator, denominator.
– Offset.
l
Selection of a target code for the read data.
Codes for the conversion of the read data and for the selection of the target code
Selection of the target code
Function block
Numerator
Denominator Offset
Code
Subcode
Examples
FEVAN1
C1093
C1094
C1095
C1091
C1092
FEVAN2
C1503
C1504
C1505
C1501
C1502
Data transmission
FEVANx-FAIL
FEVANx-BUSY
FEVANx-LOAD
Correct transmission
Wrong transmission
Fig. 3−86
Signal flow
Transmission errors may occur if
l
no target code is available,
l
no target subcode is available,
l
the data transmitted are out of the target code limits,
l
the target code is inhibited since it may only be written if the controller is inhibited. Inhibit the
controller (see code table).
Cyclic data transmission
F E V A N 1 - I N
C 1 0 9 8
C 1 0 9 6
C 1 0 9 3
C 1 0 9 4
C T R L
+
+
C 1 0 9 5
S & H
C 1 0 9 9
F E V A N 1 - L O A D
C 1 0 9 7
C 1 0 9 0
C o d e / S u b c o d e
( C x x x x / y y y )
C 1 0 9 2
C 1 0 9 1
F E V A N 1 - B U S Y
F E V A N 1 - F A I L
F E V A N 1
N O T 1
1
N O T 1 - O U T
N O T 1 - I N
C 0 8 4 1
C 0 8 4 0
Fig. 3−87
Example for a cyclic data transmission to a target code