Start via touch probe initiator (terminal x5/e5), Function library, Function blocks – Lenze EVS9332xS User Manual
Page 125: Stop

Function library
Function blocks
3.2.26
Digital frequency ramp function generator (DFRFG)
3−73
l
EDSVS9332S−EXT EN 2.0
3.2.26.6
Start via touch probe initiator (terminal X5/E5)
Stop!
In the default setting the terminal X5/E5 is assigned to another function.
Function
l
Set C0757 = 1.
l
The function is activated by simultaneously setting the inputs:
– DFRFG−QSP and DFRFG−RESET = HIGH.
l
Starting procedure:
– Signals at DFRFG−QSP and DFRFG−RESET = LOW.
– Otherwise touch probe signals are ignored.
l
A LOW−HIGH edge at terminal X5/E5 starts the process:
t
DFRFG-RESET
DFRFG-QSP
Touch-Probe X5/E5
DFRFG-OUT
DFRFG-IN
Fig. 3−70
Start via touch probe initiator (terminal X5/E5)
This manual is related to the following products: