7 and operation (and), And operation (and), Function library – Lenze EVS9332xS User Manual
Page 76: Function blocks

Function library
Function blocks
3.2.7
AND operation (AND)
3−24
l
EDSVS9332S−EXT EN 2.0
3.2.7
AND operation (AND)
Purpose
With this function digital signals can be logically ANDed. These links can be used to control functions
or to create status information.
AND1
&
AND1-IN1
AND1-IN2
AND1-IN3
AND1-OUT
C0821/1
C0821/2
C0821/3
C0820/1
C0820/2
C0820/3
Fig. 3−13
AND operation (AND1)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
AND1−IN1
d
C0821/1
bin
C0820/1
2
1000
−
AND1−IN2
d
C0821/2
bin
C0820/2
2
1000
−
AND1−IN3
d
C0821/3
bin
C0820/3
2
1000
−
AND1−OUT
d
−
−
−
−
−
−
AND2
&
AND2-IN1
AND2-IN2
AND2-IN3
AND2-OUT
C0823/1
C0823/2
C0823/3
C0822/1
C0822/2
C0822/3
Fig. 3−14
AND operation (AND2)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
AND2−IN1
d
C0823/1
bin
C0822/1
2
1000
−
AND2−IN2
d
C0823/2
bin
C0822/2
2
1000
−
AND2−IN3
d
C0823/3
bin
C0822/3
2
1000
−
AND2−OUT
d
−
−
−
−
−
−