3.2.26
Digital frequency ramp function generator (DFRFG)
3−69
l
EDSVS9332S−EXT EN 2.0
3.2.26
Digital frequency ramp function generator (DFRFG)
Purpose
The drive (motor shaft) is synchronised to a digital frequency (phase selection). The drive then
performs a phase−synchronous operation with the digital frequency.
FB_dfrfg1
C 0 7 5 1
D F R F G 1 - O U T
C 0 7 6 4 / 3
D F R F G 1 - R E S E T
D F R F G 1
C 0 4 2 9
C 0 7 6 4 / 2
C 0 7 6 4 / 1
C 0 7 6 0
C 0 7 5 9
D F R F G 1 - Q S P
D F R F G 1 - S T O P
C 0 7 6 1
C 0 7 6 5
C 0 7 5 8
D F R F G 1 - I N
C 0 7 5 2
C 0 7 5 4
S
R
Q
D F R F G 1 - F A I L
D F R F G 1 - S Y N C
C T R L
C 0 7 5 3
E 5
X 5
1
0
C 0 7 5 7
C 0 7 5 6
C 0 7 5 5
0
C 0 7 6 6
Fig. 3−65
Digital frequency ramp function generator (DFRFG1)
Signal
Source
Note
Designation
Type
DIS
DIS format
CFG
List
DFRFG1−SET
phd
C0769
−
C0768
−
Initial speed
DFRFG1−IN
phd
C0765
dec [rpm]
C0758
4
Speed/Phase setpoint
DFRFG1−QSP
d
C0764/1
bin
C0759
2
HIGH = quick stop
DFRFG1−STOP
d
C0764/2
bin
C0760
2
HIGH = save setpoint
DFRFG1−RESET
d
C0764/3
bin
C0761
2
HIGH = reset
DFRFG1−OUT
phd
−
−
−
−
Speed/Phase setpoint
DFRFG1−SYNC
d
−
−
−
−
HIGH = drive runs synchronously
DFRFG1−FAIL
d
−
−
−
−
HIGH = phase difference exceeded
Function
l
Profile generator
l
Quick stop
l
Ramp function generator stop
l
RESET
l
Detect phase difference
l
Start via touch probe initiator (terminal X5/E5)
l
Correction of the touch probe initiator (terminal X5/E5)