Input value with sign reversal (phint3), Function library, Function blocks – Lenze EVS9332xS User Manual
Page 206

Function library
Function blocks
3.2.53
Phase integrator (PHINT)
3−154
l
EDSVS9332S−EXT EN 2.0
3.2.53.3
Input value with sign reversal (PHINT3)
C1150 = 2
The input PHINT3−LOAD is state−controlled (HIGH level).
l
PHINT3−LOAD = HIGH
– The integrator is loaded with the input value at PHINT3−SET.
– Sets the output PHINT3−STATUS = LOW.
P H I N T 3 - O U T
P H I N T 3 - S T A T U S
C 1 1 5 1
- C 1 1 5 1
C h a n g e o f s i g n a t t h e i n p u t
Fig. 3−143
Function of PHINT3 with sign reversal of the input value at C1150 = 2
l
The FB integrates speed or velocity values at PHINT3−IN to a phase (distance).
l
PHINT3−OUT outputs the count of the bipolar integrator.
– A positive value at PHINT3−IN increments the integrator (count is increased).
– A negative value at PHINT3−IN decrements the integrator (count is reduced).
l
If the counter content exceeds the value of (+) C1151
– the value of C1151 is subtracted from the counter content,
– switches PHINT3−STATUS = HIGH for 1 ms.
l
If the counter content falls below the value of () C1151
– the value of C1151 is added to the counter content,
– switches PHINT3−STATUS = HIGH for 1 ms.