Possible axis synchronisations, Function library, Function blocks – Lenze EVS9332xS User Manual
Page 228

Function library
Function blocks
3.2.63
Multi−axis synchronisation (SYNC1)
3−176
l
EDSVS9332S−EXT EN 2.0
Function
l
Possible axis synchronisations (chapter 3.2.63.1)
l
Cycle times (chapter 3.2.63.2)
l
Phase displacement (chapter 3.2.63.3)
l
Synchronisation window for synchronisation via terminal (SYNC WINDOW) (chapter 3.2.63.4)
l
Correction value of phase controller (SYNC CORRECT) (chapter 3.2.63.5)
l
Fault indications (chapter 3.2.63.6)
l
Configuration examples (chapter 3.2.63.7)
l
3.2.63.1
Possible axis synchronisations
Operating mode
Code
Value
Function
C1120
0
FB without function.
Assigns the data at the inputs directly to the outputs.
1
CAN Sync active
Synchronises the controllers to the sync telegram of the system bus.
2
Terminal Sync active
Synchronises the controllers to the sync signal of terminal X5/E5.
Synchronisation time
In addition to certain mains connection and initialisation time of the controller, the FB SYNC1 also
requires a synchronisation time.
The synchronisation time depends on
l
the baud rate of the system bus (CAN−SYNC),
l
the starting time (reception of the first SYNC telegram / signal),
l
the time between the SYNC telegrams,
l
the SYNC correction factor (C0363),
l
the operating mode of the FB SYNC1.