Trip-reset, Function library – Lenze EVS9332xS User Manual
Page 112

Function library
Function blocks
3.2.23
Control of the drive controller (DCTRL)
3−60
l
EDSVS9332S−EXT EN 2.0
3.2.23.5
TRIP−RESET
Resets a pending trip as soon as the cause of malfunction has been removed. If the cause is still
active, no reaction occurs.
l
The function can be controlled by four inputs
– Control word CAN−CTRL bit 11 of CAN−IN1
– Control word AIF−CTRL bit 11 of AIF−IN
– Control word C0135 bit 11
– Free input DCTRL−TRIP−RESET
l
All inputs are linked by an OR−operation.
l
The function can only be performed by a LOW−HIGH edge of the signal resulting from the OR
operation.
l
C0136/1 displays the control word C0135
)
Note!
If one of the inputs is set to HIGH, it is not possible that a LOW−HIGH edge will
occur on the resulting signal.
This manual is related to the following products: