2 speed control (c0005 = 1000), Speed control (c0005 = 1000), Application examples – Lenze EVS9332xS User Manual
Page 242

Application examples
4.2
Speed control (C0005 = 1000)
4−4
l
EDSVS9332S−EXT EN 2.0
4.2
Speed control (C0005 = 1000)
Tip!
The most important settings can be found in the menu: "Short Setup / Speed mode" of the XT keypad
or in the menu "Short setup / Speed mode" in Global Drive Control.
Enter motor type (contains all nameplate data of the motor)
C0173
xxx
Enter UG limit (mains voltage)
C0086
000
Enter motor data manually
Enter maximum motor current
C0022 xxxA Determine
Imax
Enter controller configuration
C0005
1000
Select speed control
C0025
xxx
Enter feedback system
Speed setpoint settings
C0011
xxx rpm
Determine max. speed
C0012
xxx s
Set acceleration time
C0013
xxx s
Set deceleration time
C0105
xxx s
Set QSP deceleration time
Application parameters
C0070
xxx
Vp n−controller
C0071
xxx
Tn n−controller
Save parameters
C0003
xxx
Save all parameters