Application examples – Lenze EVS9332xS User Manual
Page 245

Application examples
4.3
Torque control with speed limitation (C0005 = 4000)
4−7
l
EDSVS9332S−EXT EN 2.0
4.3
Torque control with speed limitation (C0005 = 4000)
Tip!
The most important settings can be found in the menu: "Short Setup / Speed mode" of the operating
module or in the menu "Short setup / Speed mode" in Global Drive Control.
Enter motor type (contains all nameplate data of the motor)
C0173
xxx
Enter UG limit (mains voltage)
C0086
000
Enter motor data manually
Enter maximum motor current
C0022 xxxA Determine
Imax
Enter controller configuration
C0005
4000
Select torque control
C0025
xxx
Enter feedback system
Speed setpoint settings
C0011
xxx rpm
Determine max. speed
C0105
xxx s
Set QSP deceleration time
Speed limitation
C0472/4
xxx % nmax
Determine lower speed limit
Application parameters
C0070
xxx
Vp n−controller
C0071
xxx
Tn n−controller
Save parameters
C0003
xxx
Save all parameters