3.2.42
Monitor outputs of monitoring system (MONIT)
3−124
l
EDSVS9332S−EXT EN 2.0
MONIT outputs
MONIT output
Description
CE0
Communication error − automation interface (AIF)
CE1
Communication error − process data input object CAN1_IN
CE2
Communication error − process data input object CAN2_IN
CE3
Communication error − process data input object CAN3_IN
CE4
BUS−OFF state of system bus (CAN)
EEr
External monitoring, triggered via DCTRL
H05
Internal fault (memory)
H07
Internal fault (power section)
H10
Thermal sensor error − heatsink
H11
Thermal sensor error − inside the device
LP1
Motor phase failure
LU
Undervoltage in the DC bus
nErr
Speed control error
NMAX
Maximum speed (C0596) exceeded
OC2
Earth fault − motor cable
OC5
I x t overload
OC6
I
2
x t overload
OC8
I
2
x t overload advance warning
OH
Heatsink temperature > +90
°C
OH3
Motor temperature > +150
°C threshold
(temperature detected via resolver or incremental value encoder)
OH4
Heatsink temperature > C0122
OH7
Motor temperature > C0121
(temperature detected via resolver or incremental value encoder)
OH8
Motor temperature measured via inputs T1 and T2 too high
OU
DC−bus overvoltage
P03
Following error
P16
Faulty transmission of sync telegram on system bus (CAN)
P19
Limitation of input values at X9
PL
Error during rotor position adjustment
Sd2
Resolver error at X7
Sd3
Encoder error at X9
Sd5
Encoder error at X6 pins 1 and 2
Sd6
Thermal sensor error − motor (X7 or X8)
Sd7
Absolute value encoder at X8
Initialisation error or communication error during rotor position adjustment
Sd8
Sin/cos encoder at X8 transmits no or inconsistent data