Synchronisation mode
For the synchronisation, different modes are available which can be set under C0534.
C0534
Synchronisation mode
Note
0
Inactive
Function inactive
1
Continuous synchronisation with correction in the shortest
possible way
2
Continuous synchronisation with correction in the shortest
possible way
A LOW−HIGH edge at DFSET−0−Pulse initiates continuous
synchronisation
10
One−time synchronisation, an angular deviation is corrected in
the shortest possible way
11
One−time synchronisation, an angular deviation is corrected in
CW direction
A LOW−HIGH edge at DFSET−0−Pulse initiates a one−time
synchronisation
12
One−time synchronisation, an angular deviation is corrected in
CCW direction
13
One−time synchronisation, an angular difference is determined
between setpoint pulse and actual pulse and is corrected to the
corresponding direction of rotation according to the sign
Code C0528/1 displays the number of increments (angular difference) between the setpoint pulse