Function library, Function blocks, Setpoint input – Lenze EVS9332xS User Manual
Page 74: Actual value input and, Parameter control, Special features of ain1, The signal is read cyclically (1 ms), Special feature of ain2, The signal is read cyclically every 250 ms

Function library
Function blocks
3.2.6
Analog inputs via terminal X6/1, X6/2 and X6/3, X6/4 (AIN)
3−22
l
EDSVS9332S−EXT EN 2.0
3.2.6
Analog inputs via terminal X6/1, X6/2 and X6/3, X6/4 (AIN)
Purpose
These function blocks are the interface for analog signals as the
l
setpoint input,
l
actual value input and
l
parameter control.
C0034
1
2
AIN1
+
+
AIN1-OUT
AIN1-GAIN
AIN1-OFFSET
C0404/1
C0404/2
C0402
C0403
C0400
Fig. 3−10
Analog input via terminal X6/1, X6/2 (AIN1)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
AIN1−OFFSET
a
C0404/1
dec [%]
C0402
1
19502
−
AIN1−GAIN
a
C0404/2
dec [%]
C0403
1
19504
−
AIN1−OUT
a
C0400
−
−
−
−
−
Special features of AIN1
l
A dead band element can be integrated into the output signal at AIN1 via code C0034.
Together with the jumper position X2 (controller front) the function 4 ... 20 mA can be
implemented as a master current value.
l
The signal is read cyclically (1 ms).
3
4
AIN2
+
+
AIN2-OUT
AIN2-GAIN
AIN2-OFFSET
C0409/1
C0409/2
C0407
C0408
C0405
Fig. 3−11
Analog input via terminal X6/3, X6/4 (AIN2)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
AIN2−OFFSET
a
C0409/1
dec [%]
C0407
1
19503
−
AIN2−GAIN
a
C0409/2
dec [%]
C0408
1
19505
−
AIN2−OUT
a
C0405
−
−
−
−
−
Special feature of AIN2
l
The signal is read cyclically every 250
ms.