30 freely assignable digital outputs (digout), Freely assignable digital outputs (digout), Function library – Lenze EVS9332xS User Manual
Page 137: Function blocks

Function library
Function blocks
3.2.30
Freely assignable digital outputs (DIGOUT)
3−85
l
EDSVS9332S−EXT EN 2.0
3.2.30
Freely assignable digital outputs (DIGOUT)
Purpose
Conditioning of the digital signals and output at the terminals X5/A1 to X5/A4.
A1
A2
A3
A4
1
0
C0118/1...4
DIGOUT
DIGOUT1
DIGOUT2
DIGOUT3
DIGOUT4
C0117/1
C0117/2
C0117/3
C0117/4
C0444/4
C0444/3
C0444/2
C0444/1
X5
1
Fig. 3−79
Freely assignable digital outputs (DIGOUT)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
DIGOUT1
d
C0444/1
bin
C0117/1
2
15000
−
DIGOUT2
d
C0444/2
bin
C0117/2
2
10650
−
DIGOUT3
d
C0444/3
bin
C0117/3
2
500
−
DIGOUT4
d
C0444/4
bin
C0117/4
2
5003
−
Function
The terminals X5/A1 to X5/A4 are updated every millisecond. The level for every output can be
inverted. For this, proceed as follows:
l
Select code C0118 with corresponding subcode (e.g. subcode 3 for output X5/A3)
l
Enter the desired level as a parameter:
– 0 = Level not inverted (HIGH active)
– 1 = Level inverted (LOW active)