3.2.53
Phase integrator (PHINT)
3−152
l
EDSVS9332S−EXT EN 2.0
3.2.53.1
Constant input value (PHINT1 and PHINT2)
P H I N T x - O U T
+ 3 2 7 6 7 r e v .
- 3 2 7 6 7 r e v .
+ 3 2 0 0 0
- 3 2 0 0 0
t
P H I N T x - F A I L
t
Fig. 3−141
Function of PHINTx with constant input value
l
The FB integrates speed or velocity values at PHINTx−IN to a phase (distance).
l
PHINTx−OUT outputs the count of the bipolar integrator.
– A positive value at PHINTx−IN increments the integrator (count is increased).
– A negative value at PHINTx−IN decrements the integrator (count is reduced).
l
If the count exceeds the value of +32767 encoder revolutions (
¢ +2147483647 inc)
– an overflow occurs. The counting is continued with the value −32768.
– PHINTx−FAIL switches to HIGH when the value
w +32000 is reached.
PHINTx−FAIL = HIGH.
l
If the count falls below the value of −32768 encoder revolutions (
¢ −2147483648 inc)
– an overflow occurs. The counting starts at the value +32767.
– PHINTx−FAIL switches to HIGH when the value
v −32000 is reached.
l
PHINT
X
−RESET = HIGH
– sets the integrator to 0
– sets PHINTx−OUT = 0, as long as a HIGH level is applied to PHINTx−IN.
– sets PHINTx−FAIL = LOW.