27 digital frequency processing (dfset), Digital frequency processing (dfset), Function library – Lenze EVS9332xS User Manual
Page 127: Function blocks

Function library
Function blocks
3.2.27
Digital frequency processing (DFSET)
3−75
l
EDSVS9332S−EXT EN 2.0
3.2.27
Digital frequency processing (DFSET)
Purpose
Conditions the digital frequency for the controller. Selection of stretch factor, gearbox factor and
speed trimming or angular trimming.
*
a
b
b
a
*
a
b
b
a
+
+
1
0
+
+
C0537
C0536/2
C0536/1
C0033
C0533
C0530
C0252
C0536/3
C0538/2
C0539
DFSET
DFSET-NOUT
+
-
DFSET-A-TRIM
DFSET-N-TRIM
DFSET-RAT-DIV
DFSET-RESET
DFSET-IN
DFSET-PSET
DFSET-VP-DIV
DFSET-POUT
DFSET-SET
C0538/3
+
+
C0253
C0531
C0535
C0532
3
1
2
1
X5/E4
X9/6,7
MCTRL-PHI-ACT
C0538/1
DFSET-0-PULSE
DFSET-ACK
C0522
C0524
C0520
C0527
C0526
C0551
*
C0529
C0528/1
C0528/2
CTRL
DFSET-PSET2
C1258
DFSET-N-TRIM2
+
+
C0546
C0534
C0429
C0528/3
C0528/4
2
3
X5/E5
C0521
C0523
MCTRL-PHI-ACT
C0525
C1255
fb_dfset
Fig. 3−71
Digital frequency processing (DFSET)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
DFSET−IN
phd
C0539
dec [rpm]
C0520
4
Speed/angle setpoint
DFSET−N−TRIM
a
C0537
dec [%]
C0524
1
Speed trimming in [%] of C0011
DFSET−N−TRIM2
phd
C1258
dec [rpm]
C1255
4
Speed trimming in [rpm] of C0011
DFSET−A−TRIM
a
C0536/3
dec [inc]
C0523
1
Angular trimming 100% = 16384 inc
DFSET−VP−DIV
a
C0536/1
dec
C0521
1
Numerator of stretch factor 100 % = 16384 inc
DFSET−RAT−DIV
a
C0536//2
dec
C0522
1
Numerator of gearbox factor 100 % = 16384 inc
DFSET−0−PULSE
d
C0538/1
bin
C0525
2
HIGH = Enabling of zero pulse synchronisation
DFSET−SET
d
C0538/3
bin
C0527
2
·
HIGH = Sets angle integrators to equal values
·
LOW−HIGH edge sets DFSET−PSET = 0
·
HIGH−LOW edge sets DFSET−PSET = current value
of MCTRL−PHI−SET
·
DFSET−SET has a higher priority than DFSET−RESET
DFSET−RESET
d
C0538/2
bin
C0526
2
·
HIGH = Sets position difference = 0
·
HIGH = Sets DFSET−PSET and DFSET−PSET2 = 0
DFSET−NOUT
a
−
−
−
−
In [%] of nmax (C0011)
DFSET−POUT
phd
−
−
−
−
Speed/angle setpoint
DFSET−PSET
ph
−
−
−
−
Following error for angle controller
DFSET−PSET2
ph
−
−
−
−
Angle setpoint 65536 inc = 1 revolution
DFSET−ACK
d
−
−
−
−
HIGH = Synchronising is performed