Function library, Function blocks, 17 signal conversion (conv) – Lenze EVS9332xS User Manual
Page 100: Conv3, Conv4, Conv5

Function library
Function blocks
3.2.17
Signal conversion (CONV)
3−48
l
EDSVS9332S−EXT EN 2.0
CONV3
CONV3
CONV3-OUT
CONV3-IN
C0953
C0952
C0950
C0951
Fig. 3−44
Function block CONV3
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
CONV3−IN
phd
C0953
dec [rpm]
C0952
4
1000
CONV3−OUT
a
−
−
−
−
−
Limited to ±199.99 %
This function block is used to convert speed signals into analog signals.
The conversion is done according to the formula:
CONV3−OUT
+ CONV3−IN @
100 %
15000 rpm
@ C0950
C0951
CONV4
CONV4
CONV4-OUT
CONV4-IN
C0958
C0957
C0955
C0956
Fig. 3−45
Function block CONV4
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
CONV4−IN
phd
C0958
dec [rpm]
C0957
4
1000
CONV4−OUT
a
−
−
−
−
−
Limited to ±199.99 %
This function block is used to convert speed signals into analog signals.
The conversion is done according to the formula:
CONV4−OUT
+ CONV4−IN @
100 %
15000 rpm
@ C0955
C0956
CONV5
CONV5
CONV5-OUT
CONV5-IN
C0658
C0657
C0655
C0656
Fig. 3−46
Function block CONV5
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
CONV5−IN
a
C0658
dec [%]
C0657
1
1000
CONV5−OUT
phd
−
−
−
−
−
Limited to ±29999 rpm
This function block is used to convert analog signals into speed signals.
Conversion according to formula:
CONV5−OUT
+ CONV5−IN @
15000 rpm
100 %
@ C0655
C0656