Electrical installation – Lenze EVF9333 User Manual
Page 211

Electrical installation
Wiring of digital frequency input / digital frequency output
l
211
EDKVF9333V DE/EN/FR 7.1
B
Enable (EN)
Lamp
control (LC)
GND
Z
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
A
X9
X10
< 50 m
A
B
Z
A
A
B
Z
B
Z
9300VEC019
Fig. 5−33
Connection of digital frequency input (X9) / digital frequency output (X10)
X9
Slave drive
Signals for CW rotation
X10 Master drive
Cores twisted in pairs
X9 − Digital frequency input
Connector: Pin, 9−pole, Sub−D
Pin
1
2
3
4
5
6
7
8
9
Signal
B
A
A
+5 V
GND
Z
Z
LC
B
0.14 mm
2
(AWG 26)
0.5 mm
2
(AWG 20)
0.14 mm
2
(AWG 26)
0.5 mm
2
(AWG 20)
0.14 mm
2
(AWG 26)
X10 − Digital frequency output
Connector: Socket, 9−pole, Sub−D
Pin
1
2
3
4
5
6
7
8
9
Signal
B
A
A
+5 V
GND
Z
Z
EN
B
0.14 mm
2
(AWG 26)
0.5 mm
2
(AWG 20)
0.14 mm
2
(AWG 26)
0.5 mm
2
(AWG 20)
0.14 mm
2
(AWG 26)
This manual is related to the following products: