EDKVF9333V DE/EN/FR 7.1
9300
Rated output current at switching frequency
Max. permissible output current at switching
frequency
1)
2/4 kHz
8 kHz
8 kHz sin 8/2 kHz
2)
16 kHz
2/4 kHz
8 kHz
8 kHz sin 8/2 kHz
2)
16 kHz
Type
I
r
[A]
I
r
[A]
I
r
[A]
I
r
[A]
I
r
[A]
I
max
[A]
I
max
[A]
I
max
[A]
I
max
[A]
I
max
[A]
EVF9321−xV
1.5
1.5
1.5
1.5
1.1
2.2
2.2
2.2
2.2
1.6
EVF9322−xV
2.5
2.5
2.5
2.5
1.8
3.7
3.7
3.7
3.7
2.7
EVF9323−xV
3.9
3.9
3.9
3.9
2.9
5.8
5.8
5.8
5.8
4.3
EVF9324−xV
7.0
7.0
7.0
7.0
5.2
10.5
10.5
10.5
10.5
7.8
EVF9325−xV
13.0
13.0
13.0
13.0
9.7
19.5
19.5
19.5
19.5
14.5
EVF9326−xV
22.3
22.3
22.3
22.3
14.6
33.5
33.5
33.5
33.5
21.8
EVF9327−xV
30.4
30.4
27.0
30.4
19.0
45.6
45.6
41.0
45.6
29.0
EVF9328−xV
44.7
44.7
41.0
44.7
29.0
67.0
67.0
61.0
67.0
43.5
EVF9329−xV
56.0
56.0
44.0
560
33.0
84.0
84.0
66.0
84.0
49.0
EVF9330−xV
84.0
84.0
55.0
84.0
43.7
126
126
82.0
126
65.6
EVF9331−xV
105
105
71.0
105
49.5
157
157
107
157
74.0
EVF9332−xV
142
142
87.0
142
55.0
213
213
130
213
83.0
EVF9333−xV
171
171
94.0
171
59.0
256
211
141
256
89.0