Standard devices in the power range 0.37 kw, Important notes, Electrical installation – Lenze EVF9333 User Manual
Page 163

Electrical installation
Standard devices in the power range 0.37 ... 11 kW
Important notes
l
163
EDKVF9333V DE/EN/FR 7.1
5.4
Standard devices in the power range 0.37 ... 11 kW
5.4.1
Important notes
To gain access to the power connections, remove the covers:
ƒ
Release the cover for the mains connection with slight pressure on the front and pull
it off to the top.
ƒ
Release the cover for the motor connection with slight pressure on the front and pull
it off to the bottom.
Installation material required from the scope of supply:
Description
Use
Quantity
Shield connection support
Support of the shield sheets for the supply cable and
motor cable
2
Hexagon nut M5
Fastening of shield connection supports
4
Spring washer
Æ 5 mm (DIN 127)
2
Serrated lock washer
Æ 5.3 mm
(DIN 125)
2
Shield sheet
Shield connections for supply cables, motor cable
2
Screw and washer assembly
M4 × 10 mm (DIN 6900)
Fastening of shield sheets
4