8 Programming

50

8.2.1 Chart speed

The standard chart speed for signal tracing
is set here.

The chart speed is selected in steps from a
table of standard chart speeds, or can be
programmed continuously to any value be-
tween 0 and 7200 mm/h.

Standard chart speeds are:

0, 5, 10, 20, 60, 120, 240, 300, 360, 600,
720, 1800, 3600 und 7200 mm/h.

The programming mode is factory-
set to standard chart speeds.

In the setup program the program-
ming mode can be changed to con-
tinuous under
Edit Chart Speed... .

For alteration on the instrument
 Section 8.5.2

Please note Section 7.2

Display

Edit

Selection/input

with keys

Enter

Continue with

FEED PAPER

E

with

step speed
programming:

FEED PAPER:
0240 mm/h

Select chart speed:

0, 5, 10, 20, 60, 120, 240,
300, 360, 600, 720, 1800,
3600, 7200 mm/h

h

,

R

E

h

forwards

R

backwards

with

continuous
speed
programming:

0000

set required chart speed

value range:
0 — 7200 mm/h

h

,

R

l

,

r

E

test:
speed value

h

forwards

R

backwards