IDEX Health & Science VS-606V7 Series User Manual
Page 99
99
•
Monitor Data (available only for read out)
Register No.
bit
Description
0020H
S
tat
us
s
ign
al
0
Run command
1 : Run
0 : Stop
1
Reverse run
1 : Reverse run
0 : Forward run
2
Inverter operation ready
1 : Ready
0 : Not ready
3
Fault
1 : Fault
4
Data setting error
1 : Error
5
Multi-function output 1
(1 : MA ON
0 : MA OFF)
6
Multi-function output 2
(1 : P1 ON
0 : OFF)
7
Multi-function output 3
(1 : P2 ON
0 : OFF)
8-F
(Not used)
0021H
F
aul
t des
c
ri
p
ti
on
0
Over current (OC)
1
Over voltage (OV)
2
Inverter overload (OL2)
3
Inverter overheat (OH)
4
(Not used)
5
(Not used)
6
PID Feedback loss (FbL)
7
External fault (EF, EFO)
Emergency stop (STP)
8
Hardware fault (Fxx)
9
Motor overload (OL1)
A
Overtorque detection (OL3)
B
(Not used)
C
Power loss (UV1)
D
Control power fault (UV2)
E
MEMOBUS communications timeover (CE)
F
Operator connection (OPR)
0022H
Dat
a
l
ink
s
tat
us
0
Data write in
1
(Not used)
2
(Not used)
3
Upper/lower limit fault
4
Consistency fault
5-F
(Not used)
0023H
Frequency reference (Unit : n152)
0024H
Output frequency (Unit : n152)
0025H-026H
(Not used)
0027H
Output current (10/1A)
0028H
Output voltage reference (1/1V)
0029H
F
aul
t c
o
n
tent
s
0
Load short circuit (SC)
1
Ground fault (GF)
2
Input open phase (PF)
3
Output open phase (LF)
4
Installed type braking resistor overheat
5
Braking transistor fault (RR)
6-F
Not used